What was found
FOUND CORROSION ON BULK CARGO DOOR CUTOUT FWD FRAME AT NUTPLATES ABOVE AND BELOW BOTTOM STOP FITTING BS 1417. REMOVED BOTTOM STOP FITTING AT BS 1417, IN BULK CARGO DOOR CUTOUT. BLENDED CORROSION OUT TO A DEPTH OF .004". MAX ALLOWABLE IS 10% (ORIG THICKENSS .63") NDI CHECKED REMAINING THICKNESS. DAMAGE REMOVED DETERMINED TO BE WITHIN LIMITS IAW SRM 53-00-15 AND 53-00-7. RESTORED FINISH IAW SRM 51-20-01. FITTING REMOVAL AND INSTALL IAW SRM 51-40-02.