As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT MLG OUTBOARD DOOR FITTING THAT ATTACHES TO ROD END FOUND DETACHED AND BROKEN UPON BLOCK IN AT OGG BY LINE SERVICEMAN. REPLACED LEFT MLG OUTBOARD DOOR FITTING WITH NEW FITTING. SAFETIED OUTBOARD ROD END BOLT. COND& SEC CK GOOD PER AMM 32-14-01. INSP RT MLG OUTBOARD DOOR FITTING, FOUND COND& SECURITY CK GOOD. OK FOR SERVICE. NO DAMAGE TO DOOR AND SURROUNDING AREA.