What was found
RIGHT PACK INOP LIGHT CAME ON PRIOR TO ENGINE START. CYCLED PACK SWITCH OPS RETURNED TO NORMAL. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE 21-51-00 FIG 103. FAULTED R INLET ACTUATOR. RESET CONTROLLER BITE CK & VERIFY GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT PACK INOP LIGHT CAME ON PRIOR TO ENGINE START. CYCLED PACK SWITCH OPS RETURNED TO NORMAL. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE 21-51-00 FIG 103. FAULTED R INLET ACTUATOR. RESET CONTROLLER BITE CK & VERIFY GOOD.