What was found
FUSELAGE INTERIOR FLOOR, BS 977 LBL 34 TO LBL 51 WL 200, FLOOR SUPPORT LOOSE AND CHAFING AT FASTENER HOLES. REPLACED FLOOR SUPPORT AT BS 977 LBL 34 TO LBL 51 WL 200 IAW SRM 51-40-02, IAW SRM 51-40-02 AND DWG 140T0530.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.