What was found
FWD CARGO COMPT FLOOR SUPPORT LOWER SURFACE ATTACH ANGLE CRACKED BS 478 LBL 47, WL 125. ATTACH ANGLE AT BS 478 LBL 47 WL 125 CRACKED 100 PERCENT ACROSS MATERIAL OUT OF LIMITS, IAW SRM 53-00-04-1A-1, NOTE (B) CRACKS ARE NOT PERMITTED. FABRICATED NEW ATTACH ANGLE IAW SRM 51-40-02/101 FIG 1 USING 7075T6, 040" LOT NR 694306, IAW BOEING PN 45T1031-5 AND INSTALLED NEW ANGLE IAW SRM 51-40-02-06-0 STEP 4 B&C.