What was found
ON WALKAROUND FOUND TWO SCRATCHES 21 INCHES AFT OF BOTTOM SIDE OF BULK CARGO PIT DOOR. BLENDED AREA, PERFORMED FLOOR PENETRANT TEST, NO CRACKS NOTED. TREATED, PRIMED & PAINTED AREAS PER SRM. DAMAGE OF BOTH SCRATCHES WITH IN LIMITS PER SRM 53-00-01/101, SILVER DOT INSTALLED.