What was found
CRACK IN ANGLE ON INTERCOSTAL AT STATION 294, WL 280, AT FWD SIDE OF MAIN ENTRY DOOR FRAME. REMOVED ANGLE AND INTERCOSTAL AT FWD SIDE OF FRAME AT STA 294, WL 280. VERIFIED NO CRACKS IN ANGLE. REINSTALLED ANGLE AND INTERCOSTAL PER SRM 51-10-02 AND SRM 51-40-02.