As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C HYD SYS PRESS " DISPLAY ON EICAS QTY READING IS .45 RF IN TIME, PUMPS OFF. T/S C HYD SYSTEM PER FIM 29-11-00 FOUND LT NR 3 OUTBOARD SPOILER ACTUATOR LEAKING AT FILTER CAP DUE TO DAMAGED O-RING. REMOVED AND REPLACED O-RING PER AMM 27-61-00. LEAK CHECK CARRIED OUT PER AMM 29-11-00. NO LEAKS. AIRCRAFT DIVERTED INTO LAX, WHERE AN UNEVENTFUL LANDING WAS MADE.