What was found
ATB - APU AUTO SHUTDOWN CLIMBING THRU FL350, FAULT LIGHT ILL AND EICAS MESSAGE "APU FAULT" DISPLAYED. ACCOMPLISHED ECU BITE, FOUND "OVERSPEED" FAULT W/NO MINI FLAGS. ACCOMP FIM 49-11-00 FIG 111. CHECKED P2 SENSE LINES. NO DEFECTS NOTED. AS PER POWERPLANT ENG, REPLACED P2 SENSOR PER AMM 49-61-04. REPLACED FCU PER AMM 49-31-01. RERACKED ECU, GND RUN-UP AND LEAK FCU/P2 SENSOR OK.