As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS SIGNIFICANT SYSTEM, EICAS STATUS ALERT. CENTER FUEL TANK AND TOTAL FUEL QTY INDICATORS BLANK. EICAS MSG 'FUEL QTY IND' DISPLAYED. FUEL QTY TEST NORMAL, DISPLAYS REMAINED BLANK AFTER TEST. PERFORMED FUEL QTY TEST. FUEL BITE AND SELF TEST ON FQIS PROCESSOR. SYSTEM TEST PASS. NO FURTHER ACTION REQUIRED PER FIM 28-41-00 FIG 104 116 AND 114.