ADP AUTO FUNCTION INOP, OPERATES NORMAL IN ON POSITION. ACCOMPLISHED FIM 29-11-00, FIGURE 109. REPLACED ADP CONTROL PRESSURE SWITCH S29 PER AMM 29-11-19. GROUND OPS AND LEAK CHECK OK. REMOVED PLACARD. CLEARED MIC SHEET. MOC NOTIFIED.