What was found
ETOPS SIGNIFICANT SYSTEM, DURING CRUISE EXPERIENCED INTERMITTENT STATUS MSG FOR FUEL QTY TOTALIZER. SYSTEM INFO RETURNED. THEN OPS NORM. T/S PER FIM 28-41-00 FIG 106,108,104. NO FAULTS FOUND AT THIS TIME, SYS OPERATES NORMALLY. OK FOR SERVICE. NO EICAS MESSAGES, MAINTENANCE EICAS MSG FUEL QTY BITE CLEARED.