What was found
ETOPS SIGNIFICANT SYSTEM, AILERON LOCK OUT CAME ON APPROACH AT 250 KTS STAYED ON FOR 1.5 MINUTES. T/S AS PER FIM 27 11 00 AILERON LOCK OUT WOULD NOT FAIL ON GROUND MCDP SHOWS NO LAST FLIGHT FAULTS REPLACED LEFT ADC AS PER MM 34 12 01 404.