As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS SIGNIFICANT SYSTEM, ATB A/C DIVERTED TO HNL. EICAS MESSAGE: L ENG BLEED OFF DISPLAYED ENG BLEED AIR VALVE OFF LIGHT ILLUM WITH SWT ON AND ENG RUNNING. DUCT PRESS 0 PSI. ACCOMPLISHED AMM 36-11-705-115. 2A TO 2I (4) 4/1/08, 2I (5) TO 2K PENDING. ACCOMPLISHED 2I (5) THRU STEP 2K, REPLACED PRVC PER AMM 36-11-19. REPLACED PRV PER AMM 36-11-18 LEAK CHK PEND ENG IDLE RUN CHK GOOD. ENG HIGH PWR RUN CHECKED GOOD.