What was found
ETOPS SIGNIFICANT SYSTEM - OVERHEAD FUEL QUANTITY TOTALIZER INTERMITTENT. ACCOMPLISHED BITE OF FQ PROCESSOR PER FIM 28-41-00 FIG 104 PROCESSOR FAULTED. REPLACED PROCESSOR PER AMM 28-41-08. OPS CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM - OVERHEAD FUEL QUANTITY TOTALIZER INTERMITTENT. ACCOMPLISHED BITE OF FQ PROCESSOR PER FIM 28-41-00 FIG 104 PROCESSOR FAULTED. REPLACED PROCESSOR PER AMM 28-41-08. OPS CHECK OK.