What was found
ETOPS SIGNIFICANT SYSTEM, APU FIRE LOOP 2 MSG ON EICAS. REPLACED UPPER APU FIRE DETECTOR ELEMENT ASSY PER AMM 26-15-02. OPS CHECK PENDING. APU FIRE DECTECTOR BITE CHECKED OK PER FIM 26-15-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM, APU FIRE LOOP 2 MSG ON EICAS. REPLACED UPPER APU FIRE DETECTOR ELEMENT ASSY PER AMM 26-15-02. OPS CHECK PENDING. APU FIRE DECTECTOR BITE CHECKED OK PER FIM 26-15-00.