What was found
ETOPS SIGNIFICANT SYSTEM - EICAS MSG L ENG PRV DISPLAYED DURING ENGINE START. RIGHT ENG BLEED LGT ILLUM MSG DISPLAYED DURING BOTH ENG STARTS AND OPS NORMAL AFTER ENGINES STABILIZED. T/S PER FIM 36-10-00 FIG 124 BIT AND VERIFY ON AIR SUPPLY MODULE FAULT RIGHT ENG PRV. FOUND TERMINAL BROKEN THAT IS ATTACHED TO THE NUMBER 1 POSITION ON PRV. REPLACED RING TERMINAL FOR NR 1 LUG. PERFORMED VERIFY TEST ON MODULE NO FAULTS, RAN ENG 2 NO BLEED LIGHT ILLUM.