What was found
ETOPS SIGNIFICANT SYSTEM, APU FAILED TO START. FAULT LIGHT ILLUM AND EICAS MSG APU FAULT DISPLAYED. SECOND ATTEMPT INDICATES EGT HIGH. PERFORMED BITE CHECK OF APU NO FAULTS, CHECKED CONDITION AND SECURITY OF APU, OIL QTY CHECK GOOD, PERFORMED SUCCESSFUL START OF APU AIR AND ELECTRIC, OPS CHECK GOOD REF AMM 49-11-00.