What was found
SEVERE CORROSION ON BULK CARGO DOOR LOWER SILL STRUCTURE, IN SECOND RIB FROM AFT AND INNER WEB, STA. 1439, TO 1450,STRINGER S-32L. WEB REPLACED IAW TI 190126693-0002, AND DWG 146T8211.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERE CORROSION ON BULK CARGO DOOR LOWER SILL STRUCTURE, IN SECOND RIB FROM AFT AND INNER WEB, STA. 1439, TO 1450,STRINGER S-32L. WEB REPLACED IAW TI 190126693-0002, AND DWG 146T8211.