As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OPEN - ETOPS SIGNIFICANT SYS - FOUND DAMAGE TO OTBD REV HALF DUCT WALL OF NR 2 ENG, TRIANGULAR DENT APPROX 24" AFT OF FWD DENT MEASURES 2 INCHES X 2 INCHES X 2 INCHES X 0.0625 INCHES DEEP. ALSO NUMEROUS SCRATCHES. OK TO CONTINUE IAW HALM105 FILE NR R0033.