What was found
RT HYD SYS PRESS EICAS ALONG WITH RT ENG PRESS LIGHT ON AT SWITCH. PRESS IS 0 WITH DEMAND PUMP OFF. REPLACED NR2 ENG HYD PUMP IAW AMM 29-11-05. CONDITION SAME. RESET NR2 ENG. FIRE HANDLE, OPS CK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT HYD SYS PRESS EICAS ALONG WITH RT ENG PRESS LIGHT ON AT SWITCH. PRESS IS 0 WITH DEMAND PUMP OFF. REPLACED NR2 ENG HYD PUMP IAW AMM 29-11-05. CONDITION SAME. RESET NR2 ENG. FIRE HANDLE, OPS CK GOOD.