As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS SIGNIFICANT SYSTEM - RT ENG OIL PRESS DISPLAYED IN "RED" AFTER ENG SHUTDOWN. (W/PRESS AT EICAS STILL INDICATES RED). REPLACED K1039 CH B R ENG EEC RESET RELAY AND K169 R FUEL/IGN CONT RELAY PER SSM 76-11-01. ACCOMPLISHED IDLE RUN RT ENG OIL PRESS IND NORMAL AFTER ENG SHUTDOWN (NO "RED INDICATION") OK FOR SVC.