What was found
NR 1 STRUT AFT FAIRING, AFT "V" ANGLE, INBD ANGLE BROKEN WERE FAIRING ATTACHES TO STRUT. FABRICATION OF REPLACEMENT PARTS IAW DWG 313T3380. MATCH DRILL REPLACEMENT FRAME DWG 313T3380-303, IAW SRMS -40-02, REV 82. ASSY FRAME AND FABRICATED PARTS IAW SRM 51-40-02 REV. 82 AND DWG 313T3380, REV H. AREAS ALODINED AND BORIC ACID ANODIZE WERE REQ AND PARTS PRIMED.