What was found
ETOPS SIGNIFICANT SYS - MX LEVEL EICAS MSG IDG OUT TEMP DISPLAYED AT TOP OF CLIMB LT IDG OUT 84, RT 107 IDG RISE LT 5 RT 8. PERFORMED FIM PROCEDURE 24-20-00-1, FIG 103, SHEET 3, BLOCK 21, IDG OUT TEMP MIC LEVEL MESSAGE CONSIDERED NUISANCE, NO ACTION REQUIRED.