What was found
ETOPS SIGNIFICANT SYS - WHILE PERFORMING OVERNIGHT/ETOPS EICAS DISPLAYED RT ENG OH LP2. FOUND UPPER FWD OVERHEAT LOOP WITH BROKEN FITTING AT RESOLVER. R & R IAW AMM 26-11-02/401 CONFIG 2. FOUND UPPER AFT OVHEAT LOOP WITH BROKEN FITTING. R & R IAW AMM ABOVE. FOUND TS43 OVERHEAT LOOP BAD R & R IAW AMM 26-11-02/401 CONFIG 2 SYS CHECKS GOOD. NO FAULTS NO MESSAGES.