What was found
LEVEL 2 CORROSION ON FLOORBEAM TOP CHORD, AT BS 654+88,LBL11 - LBL20. BLENDED AND ASSESSED BEYOND SRM 53-00-51.1A.1, REV 84 LIMITS, (0.028"). REPAIR CARRIED OUT IAW SRM 53-00-51 REV.84.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION ON FLOORBEAM TOP CHORD, AT BS 654+88,LBL11 - LBL20. BLENDED AND ASSESSED BEYOND SRM 53-00-51.1A.1, REV 84 LIMITS, (0.028"). REPAIR CARRIED OUT IAW SRM 53-00-51 REV.84.