What was found
LEVEL 2 CORROSION ON FLOORBEAM TOP CHORD AT BS 654+66 - 654+100,LBL 55. BLENDED BEYOND LIMITES IAW SRM 51-10-02-00-0, REV 84. STRAP REPLACED IAW SRM 51-04-02, REV 85. CPC APPLIED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION ON FLOORBEAM TOP CHORD AT BS 654+66 - 654+100,LBL 55. BLENDED BEYOND LIMITES IAW SRM 51-10-02-00-0, REV 84. STRAP REPLACED IAW SRM 51-04-02, REV 85. CPC APPLIED.