ETOPS SIGNIFICANT SYSTEM, RT EEC INOP LIGHT ILLUMINATED AND EICAS MESSAGE "RT ENG EEC" DISPLAYED, N1 INDICATION NORMAL. T/S PER FIM 73-21-00/101 FIG 105. CLEANED CONNECTOR AT PMC GENERATOR, RAN ENG WITH NO FAULTS. SYS OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM, RT EEC INOP LIGHT ILLUMINATED AND EICAS MESSAGE "RT ENG EEC" DISPLAYED, N1 INDICATION NORMAL. T/S PER FIM 73-21-00/101 FIG 105. CLEANED CONNECTOR AT PMC GENERATOR, RAN ENG WITH NO FAULTS. SYS OK FOR SERVICE.