Service difficulty report · Warning Light · Boeing 717200

Difficulty date
April 17, 2011
Submitted
April 18, 2011
Operation
Air carrier
Aircraft
N485HA
Make and model
Boeing 717200
Aircraft serial
55130
Aircraft time
15,023 hours, 36,429 cycles
Part
Warning Light
Condition
Illuminated
Location
Spoilers
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SPOILER INBD FAIL CAME ON AFTER TURNING OFF HYD PUMPS DURING CLIMB CHECK. REVIEWED LOG FOR LAST 7 DAYS NO SIMILAR OCCURANCE FOUND. GROUND RAN BOTH ENG & CYCLED ALL FLT CONTROLS W/HYD AUX PUMP IN ON/OFF POS. COULD NOT DUPLICATE SAME COND IAW FIM PROCEDURE 27-60 TASK 807 "L" SENSORS READOUT MATCH W/PHY POS OF SPOILER PERF REPAIR. CONFIRM SPOILER SYS RTS TEST 3X ALL PASSED OK FOR SERVICE.