What was found
AFTER START EMERGENCY LIGHTS SIGN ON AND FLASHING CYCLED EMERGENCY LIGHTS NO CHANGE. FOUND MOISTURE AND LITE CORROSION AT CONNECTOR PLUG LOCATED AT 5158VC CLEANED AND RESECURED IAW AWM 33-51-05 AND AMM 33-31. OPS CK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER START EMERGENCY LIGHTS SIGN ON AND FLASHING CYCLED EMERGENCY LIGHTS NO CHANGE. FOUND MOISTURE AND LITE CORROSION AT CONNECTOR PLUG LOCATED AT 5158VC CLEANED AND RESECURED IAW AWM 33-51-05 AND AMM 33-31. OPS CK OK.