What was found
ETOPS SIGNIFICANT SYS - FUEL QTY CHANNEL STATUS MESSAGE. BITE CHECKED FQIS PROCESSOR UNIT, FOUND "A3" FAULT. R & R FQIS PROCESSOR IAW AMM 28-41-08, OPERATION CHECK GOOD. NO FAULTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYS - FUEL QTY CHANNEL STATUS MESSAGE. BITE CHECKED FQIS PROCESSOR UNIT, FOUND "A3" FAULT. R & R FQIS PROCESSOR IAW AMM 28-41-08, OPERATION CHECK GOOD. NO FAULTS NOTED.