What was found
ETOPS SIGNIFICANT SYS- "STBY INVERTER" DISPLAYED ON EICAS. REPLACED MAIN BATTERY RELAY (K104) AND MAIN BATTERY TRANSFER RELAY (K106) IAW AMM 24-33-02, OPS CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYS- "STBY INVERTER" DISPLAYED ON EICAS. REPLACED MAIN BATTERY RELAY (K104) AND MAIN BATTERY TRANSFER RELAY (K106) IAW AMM 24-33-02, OPS CHECK OK.