What was found
RT FUSE AFT BODY WING BODY SPLICE-SCREW DAMAGE ON OTBD SIDE - DEPTH .010", DIAMETER .150" LOCATED - RBL 97.42, REAR SPAR WING/BODY AFT LOWER SPLICE PLATE. AREA REWORKED PREVIOUSLY. INSTALLED CORRECT LENGTH SCREWS. REWORK OF DAMAGED AREA CARRIED OUT IAW ANZ T.I. 190145888-0001, AND SRM 57020-70, FIG 101.