What was found
ON APPROACH, SELECTED FLAPS 15 DEGREE, GOT EICAS FLAP DISAGREE MSG HANDLE IN DETENT AND FLAP GAUGE SHOWED APPROX 10 DEGREE. FOLLOWED PROCEDURE AND LANDED WITHOUT INCIDENT, ON FINAL ALL ALERTS OFF AND SEL FLAP 25 DEGREE, FLAPS MOVED TO 25 DEGREE NORMALLY. TROUBLESHOT IAW FIM 27-51-00-1. VISUAL INSPECTION WITH NO FAULTS, INSPECTED T/E ROTARY ACTUATOR FOUND NORMAL, NON TRIPPED. RAN FLAP THRU ALL SETTING AND FOUND OK FOR SERVICE.