What was found
STAB TRIM EICAS "ON" DURING SHORT FINAL,TRIM WAS NORMAL. RERACKED STAB TRIM MODULES LT AND RT. ACCOMPLISHED FIM 22-00-04/101, FIG 108A, NO FAULTS NOTED. ACCOMPLISHED LMP MCDP TEST 65 AND 30, TEST PASS. ACFT OK TO REMAIN AT LMP STATUS "L AND 3".