What was found
RIGHT IDG TEMPERATURE SENSOR DISPLAYED IDG OUT: 80-180 IDG RISE 8-180 AT TOP OF CLIMB. ACCOMPLISHED FIM 24-20-00, REPAIRED DAMAGED WIRE, JACKED ON D10966 PLUG, IAW SWAPM 20-10-13, REPLACED RT GCU IAW 24-22-02. GROUND OPS CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT IDG TEMPERATURE SENSOR DISPLAYED IDG OUT: 80-180 IDG RISE 8-180 AT TOP OF CLIMB. ACCOMPLISHED FIM 24-20-00, REPAIRED DAMAGED WIRE, JACKED ON D10966 PLUG, IAW SWAPM 20-10-13, REPLACED RT GCU IAW 24-22-02. GROUND OPS CHECKED OK.