What was found
ETOPS SIGNIFICANT SYS - ON INITIAL CLIMB EICAS MESSAGE, RT ENG HIGH STAGE, DISPLAYED RT HI STAGE LIGHT ILLUMINATED, QRH PROCEDURES C/W, LIGHT EXTINGUISHED. CONDUCTED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00 FAULTED FAMV. TROUBLESHOT FAN AIR MODULATING VALVE. FOUND CONNECTOR TO VALVE DIRTY. CLEAN & RESEATED AND CONDUCTED OPS TEST OF SAID VALVE IAW AMM 36-11-16. OPS CHECKED GOOD. BITE CHECK NO FAULTS.