What was found
RUDDER LIMIT FAILED HIGH SPEED PROTECTION A/S UNREADABLE BOTH SIDES A/P DISENGAGED AUTOTRIM FAIL. PERFORMED AMM 34-11-00-200-801 INSPECTION OF PITOT SYS FOR ACCUMULATED WATER. LEAK CHECKED OK, IAW AMM 34-11-00-790808/8073192. FUNCTION CHECK OF AIR DATA SYS PRESSURE OK, IAW AMM 34-43-00-720-802 & 34-43-00-710-801. PERFORMED FIM 22-22-TASK 801 AUTO TRIM CHECK OK. PERFORMED AMM 23-00-00-741-811 RUDDER SYS OK. PERFORMED AMM 22-00-00-741-802 AUTOFLIGHT OK. REPLACED NR 1 & NR 2 ADIRIU, OPS CHECKED OK IAW MM 34-43-00.