What was found
ACFT DIVERTED TO AN ALTERNATE STATION. T/E FLAP DISAGREE EICAS AND CVE LIGHTS ILLUMINATED WHEN FLAPS SELECTED TO 15 DEGREES. AND STATUS T/E FLAP SHUTDOWN. ACCOMPLISHED FIM 27-51, FIG 114C, ACCOMPLISHED FSPM BITE FIM 27-58, FIG 104, ACCOMPLISHED FSEU BITE FIM 27-51, FIG 104. FOUND FAULT 27-51104, REPLACED M548 IAW AMM 27-81-11. OPS TESTED GOOD. BITE CHECKED GOOD.