What was found
EVIDENCE OF HEAT DAMAGE ON TEST PANEL SWITCHES S1 AND S5. R & R TEST PANEL, M10398. TESTED FUEL QTY, WINDOW/PROBE HEAT, HYD GEN, EQUIP COOL, DUCK LEAK, STRUT LEAK, AIR DATA LT-RT COMPUTER, IAW AMM 34-12-00, 26-18-00,30-31-00, 24-25-00,30-41-00,28-41-00. ACCOMPLISHED GROUND PROXIMITY, MLG YAW DAMPER AND STALL WARNING TEST IAW AMM 34-46-00,27-32-00,22-21-00 AND WING ANTI-ICE TEST IAW AM 30-11-00. OK FOR SERVICE.