Service difficulty report · Actuator · Airbus A330243

Difficulty date
January 24, 2014
Submitted
January 29, 2014
Operation
Air carrier
Aircraft
N392HA
Make and model
Airbus A330243
Aircraft serial
1404
Aircraft time
3,740 hours, 583 cycles
Part
Actuator
Condition
Failed
Location
Apu Fuel
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TWO TO THREE MINUTES AFTER APU SHUTDOWN, APU LP VALVE FAULT APPEARS FOR ONE MINUTE THE EXTINGUISHES. R & R APU LP FUEL SHUTOFF VALVE ACTUATOR IAW AMM 28-29-52-000-801-A. OPS CHECKED OK IAW AMM 28-29-00-710-802.