What was found
AFTER LANDING, APU FAULT AUTO SHUTDOWN. FOUND BUSS BAR NUT ON 6KA FUSE HOLDER MOUNT BACKED OFF AND ARC WELDED TO STUD. INSTALLED NEW BUSS BAR, AND REINSTALLED FUSES IAW AMM 49-42-00. OPS CHECKED NORMAL ELECTRICAL. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER LANDING, APU FAULT AUTO SHUTDOWN. FOUND BUSS BAR NUT ON 6KA FUSE HOLDER MOUNT BACKED OFF AND ARC WELDED TO STUD. INSTALLED NEW BUSS BAR, AND REINSTALLED FUSES IAW AMM 49-42-00. OPS CHECKED NORMAL ELECTRICAL. OK FOR SERVICE.