What was found
CORROSION AROUND PANEL FASTENER ATTACH HOLES 11 EA, BS 960-1005, RT KEEL BEAM LOWER CHORD FLANGE. REMOVED CORROSION AT 11 LOCATIONS DEEPEST AREA OF .068" IN AREA OF 2" X 1.5". ALL AREAS FOUND TO BE WITHIN LIMITS IAW 53-50-12-1A1. REPAIRED BLEND AREAS IAW 53-50-12-2R-2, REPAIR 2. REPAIRED NUT PLATS ATTACHMENT HOLES IAW ER 15-04802.