What was found
CORROSION AROUND PANEL FASTENER ATTACH HOLES 12 EA BS 960-1005, LT KEEL BEAM LOWER CHORD FLANGE. REMOVED CORROSION AT 12 LOCATIONS, BS 960-1005 LT KEEL BEAM LOWER CHORD FLANGE, DEEPEST AREA .066" IN AREA OF 2' X 1.5", ALL AREAS FOUND TO BE WITHIN LIMITES, IAW SRM 53-50-1A-1. REPAIRED BEAM AREA IAW 53-50-12-2R-2, REPAIR 2. REPAIRED NUT PLATE ATTACHMENT HOLES IAW ER 15-01807.