As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT FWD FUEL PUMP EICAS MESSAGE ACCOMPLISHED QRH, CONTINUE NORMAL OPERATION, FUEL 6 OF THE QRH. CHECKED CONNECTOR ON BOOST PUMP, NO SHORTS BETWEEN PHASES AND NO SHORTS TO GROUND. CHECKED WIRING BACK TO ACFT, NO SHORTS BETWEEN PHASES & NO SHORTS TO GROUND. RAN PUMP FOR 5 MINUTES, C/B CHECKED OK. ALL CHECKS IAW TASK 28-22-15 & FIM 28-22. ACFT OK FOR SERVICE.