What was found
EMERGENCY LIGHTS 39WL AND 45WL DID NOT ILLUMINATE DURING OPS CHECK OF EMERGENCY LIGHTS. CABIN CEILING LT SIDE AT FRAME 38 & 53.6. UPON INVESTIGATION FOUND CABIN CEILING EMERGENCY LIGHTS 39WL AND 45WL NOT CONNECTED. CABIN CEILING EMERGENCY LIGHT 39WL AND 45WL RECONNECTED AND TESTED SERVICEABLE IAW AMM 33-51-11-400-801-A.