What was found
DURING H-CHECK, DOOR 4 FLOOR SUPPORT FRAMES 75-76, Y-2462 JUST UNDER DOOR 4R PLAT IS CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 5-42-11, 51-44-11 AND DWG F53479320027.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING H-CHECK, DOOR 4 FLOOR SUPPORT FRAMES 75-76, Y-2462 JUST UNDER DOOR 4R PLAT IS CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 5-42-11, 51-44-11 AND DWG F53479320027.