What was found
EVIDENCE OF POSSIBLE CORROSION ON FLOOR STRUCTURE AT FRAME 16A. CORROSION BLENDED ON FLOOR STRUCTURE AT BS 12965, FRAME 16A AT 1992, IAW SRM 51-74-00, REV 89. BLEND OUT ASSESSED, NO REF FOR ALLOWABLE DAMAGE AVAILABLE. RII CARRIED OUT TO CONFIRM, LEVEL 2 CORROSION IAW GMM. FLOOR STRUCTURE REMOVED IAW SRM 51-42-11, REV 89. RES N380-027, SUBMITTED. ER/A 546160-14 RECEIVED INTENT OF STEPS 1 & 2 C/O. FLOOR STRUCTURE REINSTALLED IAW SRM 51-42-11 & 51-23-11, REV 89.