What was found
ETOPS SIGNIFICANT SYSTEM, ENGINE 1 FADEC SYS FAULT ECAM/ENG 1 OVERSPEED PROTECTION. T/S IAW TSM 73-21-89-810-818A AND FOUND J3 CONNECTOR ON PMA READING OPEN FIELD. R & R PMA STATOR IAW AMM 73-21-51. OPS NORMAL. ACFT OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM, ENGINE 1 FADEC SYS FAULT ECAM/ENG 1 OVERSPEED PROTECTION. T/S IAW TSM 73-21-89-810-818A AND FOUND J3 CONNECTOR ON PMA READING OPEN FIELD. R & R PMA STATOR IAW AMM 73-21-51. OPS NORMAL. ACFT OK FOR SERVICE.