As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOOR 1 WET AREA ,INTERCOSTAL BETWEEN Y - 450 TO Y- 953 AT FR 13A FOUND TO HAVE SUSPECT CORROSION. CORROSION REMOVAL CARRIED OUT IAW SRM 51-22-00 REV 91. BLEND DIMENSIONS, LENGTH 1.300" WIDTH. 0.900" DEPTH. 0.035" MATERIAL THICKNESS 0.085". BLEND AREA FOUND BEYOND LIMIT OF SRM 51-11-15 REV 91. CORROSION RII C/O FOR LVL 2 CORROSION IAW GMM VOL1 CHAPTER 5 1.8.2 REV 43. INTERCOSTAL REPLACED IAW DWG F53116242 AND SRM 51-72-11 REV 91. JOB COMPLETE